4333 W. Sam Houston Pkwy N., Suite 100 Houston, TX 77043 | D: +1 713 300-2700 | TF: 800 619-2861 | F: +1 713 856-6623
Phone: 800-619-2861
E-mail: sales@spectrasensors.com

Performance |
|
|
Target Components |
H2S + H2O + CO2 in Natural Gas |
|
Typical Measurement Ranges - H2S |
0-20 ± 0.5ppmv (other ranges available)
|
| Typical Measurement Ranges - H2O | 0-20 ± 2lb/MMscf (other ranges available) |
| Typical Measurement Ranges - CO2 | 0-10 ± 0.04% (other ranges available) |
|
Measurement Update Time |
H2S: 2 seconds
H2O & CO2: 1 second
Total system response is dependant on
flow rate and sample system volume
|
|
Principle of Measurement |
Tunable Diode Laser Absorption Spectroscopy
|
|
Environmental Temperature Range |
-20º to 50ºC (-4º to 122ºF)
-15º to 60ºC (5º to 140ºF) optional
|
|
Sample Inlet Pressure |
1.5-4 barG (20-50 PSIG) to enclosure inlet
|
|
Cell Temperature |
-20º to 50ºC (-4º to 122ºF)
-15º to 60ºC (5º to 140ºF) optional
|
|
Maximum Cell Pressure |
70 kPag (10 PSIG) |
| Sample Flow Rate |
H2S: 2-4L/min (4 to 8 scfh)
H2O & CO2: 0.1-2L/min (0.2 to 4 scfh)
|
| Recommended Validation |
H2O: Bureau of Mines Chilled Mirror
H2S & CO2: Binary Cal Gas Bottle with Methane Background |
Electrical |
|
|
Voltage |
100-240 VAC, 50-60 Hz standard |
|
Max Current |
3A max @ 120 VAC
1.5A nax @ 24VAC Hz
|
|
Communication |
4-20mA loop (concentration only), RS232 (all parameters)
|
| Digital Outputs |
2, 1 General Fault and 1 Hi/Lo Concentration Alarm
per measurement cell
|
| LCD Display |
Concentration, Cell Pressure and Temperature & Diagnostics |
Physical
|
|
|
Controller Enclosure |
NEMA 4X - standard |
|
Dimensions |
1450 mm H × 760 mm W × 330 mm D (57” H × 30” W × 13” D) |
|
Weight |
Approximately 154Kg (340lbs) |
|
Sample Cell Dimensions |
438mm H x 108mm W
(17-1/4” H × 4-1/4” W) |
|
Sample Cell Construction |
316L Series Polished Stainless Steel standard |
| Number of Sample Cells |
3
|
| Area Classification |
CSA Certified for Class I, Division 2,
Groups ABCD Temp Code T3C
|
|
|
|
P53
|
|||||||||||||||||||||
HEATED SAMPLE CONDITIONING |
|||||||||||||||||||||
|
The P53 Heated Sample Conditioning System ensures performance of gas analyzer by delivering a heated sample through patented technology to the analyzer. This avoids costly errors resulting from hydrocarbon dew point drop out by the maintaining at least 30ºF above the expected hydrocarbon dew point. |
The gas sample is heated inside of the regulator before and after the pressure is reduced eliminating hydrocarbon liquid condensation caused by the Joule Thomson effect during the pressure reduction. |
||||||||||||||||||||
![]() |
|||||||||||||||||||||
P53 |
|||||||||||||||||||||
HEATED SAMPLE CONDITIONING SYSTEM |
|||||||||||||||||||||
![]() |
|||||||||||||||||||||
|
|||||||||||||||||||||
PONY |
|||||||||||||||||||
HEATED PROBE ENCLOSURE |
|||||||||||||||||||
|
The Pony® Heated Probe Enclosure is designed to provide and maintain heat for the sample probe directly at the sample point with a P53 Heated Sample Conditioning System. The Pony® enclosure is an integral part of the P53, developed to install between 6” center-to-center thread-o-lets. |
Consisting of a molded, insulated, and weatherproof clam shell design, the Pony® enclosure provides easy maintenance with steel latches and chain to prevent loss of lid. Construction selections include hot press glass fiber reinforced polyester or stainless steel. |
||||||||||||||||||
![]() |
|||||||||||||||||||
PONY
|
|||||||||||||||||||
HEATED PROBE ENCLOSURE |
|||||||||||||||||||
![]() |
|||||||||||||||||||
|
|||||||||||||||||||
To request a quote online, please enter the following and we'll get back to you promptly: