Skip to Content

4333 W. Sam Houston Pkwy N., Suite 100 Houston, TX 77043 | D: +1 713 300-2700 | TF: 800 619-2861 | F: +1 713 856-6623

SS2100 - CO2 Tail Gas Recovery Unit (TGU) Feed

Product Code: 36703
 
 
 
 
 

Application Note

An application note is in development. Please view the data sheet tab for more information.

An application note is in development. For immediate information on this application please fill out our Request a Quote form, email Sales@spectrasensors.com or locate the rep in your area. Please be sure to include the product code when requesting a quote or emailing our factory or rep.

 

« Previous | Next »

Data Sheet


Performance

Target Components

CO2 in Tail Gas Recovery Unit
(TGU) Feed

Typical Measurement Ranges

0 – 30% (other ranges available)*

Typical Precision

 ±2% of Full Scale*

Measurement Response Time

1 to ~60 sec

Principle of Measurement

Tunable Diode Laser Absorption Spectroscopy
Non-differential

Environmental Temperature Range

-20º to 50ºC (-4º to 122ºF)
-10º to 60ºC (14º to 140ºF) optional

Sample Inlet Pressure

70 kPag (10 psig) typical

210 kPag (30 psig) maximum


Cell Temperature

Maintain at 50ºC +/- 0.2ºC

Maximum Cell Pressure

70 kPag (10 PSIg)

Sample Flow Rate
 
1 - 2 L/min (2.1 to 4.2 scfh)*
Validation
Certified blend of CO2 in a balance
that matches the sample
 

Electrical

Power

100-240 VAC, 50-60 Hz standard

Max Current

Controller: 1 A @ 120 VAC

Controller to Cell Cable Length

1m standard (3m, 5m & 10m available optionally)

Communication

Current Loop Output 4-20 mA Isolated,
1200 ohms @ 24 VDC max load
Serial: ASCII Text RS232C standard
Modbus RS232C
Digital Outputs
4 ea. 12 VDC for valve operations
Scrubber (if required), Process/Val, Val 1, Val 2
5 SPDT (Form C) Dry Contact Alarms
Common Fault, Val 1 Active, Val 2 Active, Val Fail,
one user-assignable to any alarm 
LCD Display
Concentration, Cell Pressure and Temperature, Diagnostic Data
 

Physical

Controller Enclosure

NEMA 4X - 304 Stainless Steel standard

Controller Dimensions

343mm H x 305mm W x 165mm H
(13.5" H x 12" W x 6-7/16" D)*

Weight Approximately

13.1 Kg (28.6 lbs)*

Sample Cell Dimensions

0.8m cell
438 mm H × 108 mm W
(17-1/4” H × 4-1/4” W)*

Sample Cell Construction

316L Series Polished Stainless Steel standard
Number of Sample Cells
1 (single channel SS2100) or
2 (dual channel SS2100)
Area Classification
CSA Certified for Class I, Division 2,
Groups ABCD Temp Code T3C
 ll 2G Ex d llB+H2 T5; Tamb : -20 ÷ +60 °C
Dimensions with Sample System 1678 mm H x 613 mm W x 427 mm D
(66” H x 24-1/8” W x 16-13/16” D)
Weight with Sample System (approx.) 68 kg (150 lbs.)

* Application specific; consult factory

« Previous | Next »

Drawings


Typical Accessories


SS2100 ARM9 Electronics
 

80000-02199

Temperature Control Board

23000-00030

4-20 mA Current Loop Board
 

80000-02203

Power Supply Assembly, 120/240 VAC 50/60 Hz
 

80000-02300

Power Supply Assembly, 24 VDC
 

01902-17106 External Serial Output Cable

01902-30011 Keypad Assembly

24601-00002
Display Assembly
 
02203-13100
Daughter Board
 
45000-02002
Relay, DC12V SPDT 3 A/120 VAC
 

Cell (0.8m)
01902-17102
Pressure Transducer Assembly
 
02199-00001
Spares/Cleaning Kit (o-rings, fuses), AC, Viton (domestic only)
 
02199-00005
Spares Kit (o-rings, fuses), AC, Viton
 
 
 

Photos

 
 

« Previous | Next »

Request a quote

To request a quote online, please enter the following and we'll get back to you promptly:

Your Name*
Company
Email*
Address*
Address Line 2
City*
State
Zip Code
Country*
Phone
Product Code
Application Name / Stream Details
Measurement Range
Comments and Questions