SS2100 - CO2 GTL/SynGas (Sasol Process)

Tunable Diode Laser technology is perfect for fast, sensitive CO2 measurements in Synthol Reactor Tail Gas Scrubber applications.
Product Code: 65803
 
 
 
 
 

Application Note

Catalytic Reforming Unit
The Synthol process starts with synthesis gas from coal or natural gas to make hydrocarbon liquids and waxes in a Fischer-Tropsch reactor. The liquids are separated and refined to make transportation fuels and chemicals.

Critical Control of Carbon Dioxide

Carbon Dioxide must be removed prior to downstream cryogenic recovery and separation of the C2’s and C3 hydrocarbons present. Benfield Hot Potassium Carbonate systems (Fig. 1) are used for CO2 removal. Monitoring of the CO2 at the outlet is essential to the operation of the plant, and high CO2 concentrations present a shut-down situation for the plant.

Traditional Measurement Solutions
On-line gas chromatographs have been the traditional method for monitoring the levels of CO2 in cracked gas streams. Unfortunately, even with the latest in chromatography techniques, the analysis can take 3-6 minutes between measurement updates. Due to rapid changes in the acid gas concentration, this delay may not be acceptable. Also, gas chromatographs consume carrier and flame fuel cylinder gases, as well as requiring hydrocarbon-free air for flame ionization detectors, so the consumable costs of GC’s are high. Spectroscopic methods using broadband light sources and narrow band pass filters are prone to interferences from changing background concentrations. The concentrations of CO2 present are too low for Raman spectroscopy.

SpectraSensors’ Solution
The SpectraSensors SS2100 offers a new solution to this control measurement. The use of Tunable Diode Laser technology means that analysis results can be updated every second if desired. Furthermore, the high resolution that is inherent to TDL technology eliminates errors due to interferences that have hampered other spectrometric approaches. There are no consumables required for CO2 analysis at normal concentrations, so cost of ownership is low.

Validation
Validation is done with a certified blend of Carbon Dioxide in a background of Nitrogen, typically at a concentration in the middle of the measured range.

Typical Stream Compositions

Component

Unit

Typical Concentration

Min. for Application

Max. for Application

Carbon Dioxide (CO2)

ppmv

50

2

200

Hydrogen (H2)

Mole%

50

35

 

65

 

Methane (CH4)

Mole%

40

20

60

Ethane (C2H6)

Mole%

2

0

5

Ethylene (C2H4)

Mole%

2

0

5

Propylene (C2H6)

Mole%

3

0

5

Butenes

Mole%

2

0

5

H2O

Mole%

0.4

0

0.5

Total

Mole%

100

 

 

 

The background stream composition must be specified for proper calibration and measurement performance. Specify the Normal composition, along with the minimum and maximum expected values for each component, especially water, the measured component. Other stream compositions may be allowable with approval from SpectraSensors. 
 
 

« Previous | Next »

Data Sheet


Performance

Target Components

CO2 in GTL/SynGas (Sasol Process)

Typical Measurement Ranges

0 – 100 ppm* through 0 – 1000 ppm
(specify range)

Typical Precision

 ±2% of Full Scale

Measurement Response Time

1 to ~60 sec*

Principle of Measurement

Tunable Diode Laser Absorption Spectroscopy
Non-differential

Environmental Temperature Range

-20º to 50ºC (-4º to 122ºF)
-10º to 60ºC (14º to 140ºF) optional

Sample Inlet Pressure

70 kPag (10 psig) typical

210 kPag (30 psig) maximum


Cell Temperature

Maintain at 50ºC +/- 0.2ºC

Maximum Cell Pressure

70 kPag (10 PSIg)

Sample Flow Rate
 
3 - 4 L/min (6.4 to 8.5 scfh)*
Validation
Certified blend of CO2 in Nitrogen balance
 

Electrical

Power

100-240 VAC, 50-60 Hz standard

Max Current

Controller: 1 A @ 120 VAC

Controller to Cell Cable Length

1m standard (3m, 5m & 10m available optionally)

Communication

Current Loop Output 4-20 mA Isolated,
1200 ohms @ 24 VDC max load
Serial: ASCII Text RS232C standard
Modbus RS232C
Digital Outputs
4 ea. 12 VDC for valve operations
Scrubber (if required), Process/Val, Val 1, Val 2
5 SPDT (Form C) Dry Contact Alarms
Common Fault, Val 1 Active, Val 2 Active, Val Fail,
one user-assignable to any alarm 
LCD Display
Concentration, Cell Pressure and Temperature, Diagnostic Data
 

Physical

Controller Enclosure

NEMA 4X - 304 Stainless Steel standard

Controller Dimensions

343mm H x 305mm W x 165mm H
(13.5" H x 12" W x 6-7/16" D)*

Weight Approximately

13.1 Kg (28.6 lbs)*

Sample Cell Dimensions

8m Herriot Cell
559 mm H × 127 mm W
(22” H × 5” W)

Sample Cell Construction

316L Series Polished Stainless Steel standard
Number of Sample Cells
1 (single channel SS2100) or
2 (dual channel SS2100)
Area Classification
CSA Certified for Class I, Division 2,
Groups ABCD Temp Code T3C
 ll 2G Ex d llB+H2 T5; Tamb : -20 ÷ +60 °C
Dimensions with Sample System 1678 mm H x 613 mm W x 427 mm D
(66” H x 24-1/8” W x 16-13/16” D)
Weight with Sample System (approx.) 68 kg (150 lbs.)

* Application specific; consult factory

« Previous | Next »

Drawings


 

Typical Accessories


SS2100 ARM9 Electronics
 

80000-02199

Temperature Control Board

23000-00030

4-20 mA Current Loop Board
 

80000-02203

Power Supply Assembly, 120/240 VAC 50/60 Hz
 

80000-02300

Power Supply Assembly, 24 VDC
 

01902-17106 External Serial Output Cable

01902-30011 Keypad Assembly

24601-00002
Display Assembly
 
02203-13100
Daughter Board
 
45000-02002
Relay, DC12V SPDT 3 A/120 VAC
 

Herriott Cell (8m & 28m)
02101-17102
Pressure Transducer Assembly
 
02101-17103
Thermistor Assembly
 
02199-00006
Spares Kit (o-rings, fuses), AC, Viton
 
02199-00007
Cleaning Kit (domestic only)
 
 
 

Photos

 
 

« Previous | Next »

Request a quote

To request a quote online, please enter the following and we'll get back to you promptly:

Your Name*
Company
Email*
Address*
Address Line 2
City*
State
Zip Code
Country*
Phone
Product Code
Application Name / Stream Details
Measurement Range
Comments and Questions

« Previous | Next »