Skip to Content

4333 W. Sam Houston Pkwy N., Suite 100 Houston, TX 77043 | D: +1 713 300-2700 | TF: 800 619-2861 | F: +1 713 856-6623

Model SS3000 Analyzer

 
 
For H2O, CO2 and H2S the SS3000 Single Channel Analyzer is capable of measuring moisture, hydrogen sulfide and carbon dioxide using tunable diode laser technology. Any two components are measured in a single analyzer. The SS3000 delivers precise, reliable measurements and dramatically reduces maintenance costs.
 

Overview


SpectraSensors SS3000 Dual Channel Gas Analyzer is capable of measuring moisture, hydrogen sulfide or carbon dioxide in any combination. This cost effective dual channel system enhances cost savings by incorporating two sensors in one.
 
RAPID RESPONSE TIME  The SS3000 analyzer takes four measurements per second with a laser and detector and immediately averages the results. Because there is no contact with the gas, real-time measurements are not hampered by wet-up or dry-down times as with surfaced-based sensors.

TRUSTWORTHY MEASUREMENTS Dependable data is an essential element in the quest for improved safety and quality. The SS3000 analyzer delivers precise, reliable measurements using patented Tunable Diode Laser (TDL) technology developed by NASA.
 
The TDL sensor never comes into contact with the sample gas stream. The result is a sensor which does not suffer from contamination or drift due to vapor impurities such as glycol, methanol or amines.
 
The SS3000 dramatically reduces intangible but real costs associated with unreliable gas measurements. By eliminating added processing steps, detecting poor gas quality and the possibility of costly damage to equipment that can result from sensors that produce incorrect data.

TECHNOLOGY The analyzer works by shining a laser beam through the sample cell. The laser beam is selected to interact only with the measured compound, creating an absorption signal. The higher the concentration of H2O, H2S or CO2, the greater absorption of light and the stronger the corresponding absorption signal. Spectrum Software analyzes these absorption peaks to produce very accurate and repeatable measurements. Since the calculation is a direct, fundamental measurement, the amount of H2O, H2S or CO2 present can be measured in real-time.
 
LOW COST OF OWNERSHIP Operating costs are dramatically reduced by eliminating the cost of consumables, extra sensor heads, labor and overhead associated with excessive maintenance.

 

« Previous | Next »

Industries


The SS3000 Model measures Moisture, Carbon Dioxide and Hydrogen Sulfide in Natural Gas Production.
 

Drawings


SS3000 Dual Channel with Stainless Steel Enclosure (NEMA 7,4X) – 1 stream
 
 
 
SS3000 Dual Channel with Stainless Steel Enclosure (NEMA 7,4X) – 2 stream
 

 
SS3000 with Exd aluminum enclosure (NEMA 7,4)
 
 

« Previous | Next »

Manual



 
 

Photos

 

« Previous | Next »

Request a Quote

To reqest a quote online, please enter the following and we'll get back to you promptly:

Your Name*
Company
Email*
Address*
Address Line 2
City*
State
Zip Code
Country*
Phone
Product Code
Application Name / Stream Details
Measurement Range
Comments and Questions

« Previous | Next »